Toyota Avalon (XX50): Relay

On-vehicle Inspection

ON-VEHICLE INSPECTION

PROCEDURE

1. INSPECT MG CLT RELAY (for 2GR-FKS)

*a

MG CLT Relay

(a) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

3 - 5

Battery voltage applied between terminal 1 and 2

Below 1 Ω

3 - 5

Battery voltage not applied between terminal 1 and 2

10 kΩ or higher

If the result is not as specified, replace the MG CLT relay.

2. INSPECT PTC HEATER RELAY (for A25A-FXS)

*a

PTC Heater Relay

(a) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

3 - 5

Auxiliary battery voltage applied between terminal 1 and 2

Below 1 Ω

3 - 5

Auxiliary battery voltage not applied between terminal 1 and 2

10 kΩ or higher

  • If the result is not as specified, replace the PTC heater relay.

Refrigerant

Room Temperature Sensor

See More:

Toyota Avalon (XX50) 2019-2022 Service & Repair Manual > Sfi System: Fuel Rail / System Pressure - Too High (P008800). Mass or Volume Air Flow Sensor "A" Circuit Short to Battery (P010012,P010014). Mass or Volume Air Flow Sensor "A" Signal Plausibility Failure (P010064
Fuel Rail / System Pressure - Too High (P008800) DESCRIPTION Refer to DTC P008700. Click here DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory Note P008800 Fuel Rail / System Pressure - Too High Although the ECM is requesting the fuel pump assembly (for high pressure side) to o ...

Toyota Avalon (XX50) 2019-2022 Service & Repair Manual

© 2026 Copyright vehicle-interior.tavalon.net
0.1216